[目的]优化全自动凯氏定氮法检测乳制品中蛋白质含量的检测条件。[方法]采用凯氏定氮法检测乳制品中蛋白质含量,通过对比不同称样量、消化时间及消化后冷却时间对检测结果的影响,选择最佳参数条件,实现对全自动凯氏定氮法检测方法的优化,并提高检测效率。[结果]混合均匀的乳制品,一定范围内称样量对结果的影响不大,精密度符合国标要求,但是灭菌乳、调制乳、饮料称样量增多,精密度对应越好,发酵乳则称样过多后精密度有所下降;在230 ℃消化30 min,420 ℃时消化80 min,可消化完全,精密度可以控制在1%以内;消化后样品及时冷却,48 h内,对检测结果没有显著差异。[结论]通过本试验证明,使用凯氏定氮法检测乳制品中蛋白质含量时,调整称样量、消化时间、冷却时间,对检测结果没有显著影响。
[Objective]To optimize the detection conditions of automatic Kjeldahl method for detecting protein content in dairy products. [Method]The protein content in dairy products was detected by Kjeldahl method. By comparing the effects of different sample weights,digestion time and cooling time after digestion on the detection results,the best parameters and conditions were selected to optimize the automatic Kjeldahl method and improve the detection efficiency. [Result]For dairy products with uniform mixing,the influence of sample weight within a certain range on the results was small,and the precision met the requirements of the national standard. However,the more the sample weight of sterilized milk,prepared milk and beverage was,the better the precision was. For fermented milk,the more the sample weight was,the lower the precision was. Digest at 230 ℃ for 30 min and 420 ℃ for 80 min, which can be completely digested,and the precision can be controlled within 1%.The samples were cooled in time after digestion,and there was no significant difference in the test results within 48 hours. [Conclusion] Through this test, it is proved that when using Kjeldahl method to detect protein content in dairy products, adjusting sample weight, digestion time and cooling time has no significant impact on the test results.
[1] 赵艳萍,陈平,张蕾.全自动凯氏定氮仪测定食品中蛋白质分析[J].科技创新导报,2014,11(8):45.
[2] 史玮,孙莹,徐振斌.凯氏定氮法测定粮食蛋白质含量方法研究[J].粮食科技与经济,2013,38(5):31-32.
[3] 司徒茵,凌育昕.蛋白质检测方法的研究[J].食品界,2021(4):123.
[4] 方亚敏,冯蓓健,杨滨.食品中蛋白质两种测定方法比较[J].上海预防医学杂志,2009,21(8):381-382.
[5] 雷泽夏,段苏洋,朱建宇,王睿智,李杭.食品中蛋白质的含量方法测定[J].现代食品,2016(06):100-101.
[6] 赵文英,花锦,张梨花,等.近红外光谱测定不同鲜肉肉糜中蛋白质含量[J].食品与机械,2017,33(1):48-50,118.
[7] 姬玉梅. 三种小麦蛋白质测定方法的比较[J].湖北农业科学,2011,50(12):2533-2535.
[8] 侯向昶,董浩,罗东辉,等.乳与乳制品中蛋白质检测方法的研究现状与进展[J].乳业科学与技术,2013,36(3):28-31.
[9] 吕晓超,封雪,惠香,等.食品中蛋白质检测方法研究进展[J].食品安全导刊,2022(8):143-145.
[10] 张笑言. 食品检验中蛋白质测定方法的优化[J].中国食品,2019(Z1):234-235.
[11] 中华人民共和国国家卫生和计划生育委员会.GB5009.5-2016食品安全国家标准食品中蛋白质的测定[S].